Communication Ports View
3U Rack Installation View
Front View
192V 6Ah LiFePO4 UPS Battery

192V 6Ah LiFePO4 UPS Battery
(3U Rack Module / 8kVA Backup)

Configured as a 192V 6Ah LiFePO4 battery pack in a 3U rack-mount format, this model is presented for compatible high-voltage UPS applications up to 8kVA. Confirm the target system’s DC bus, charging profile, BMS interface, connector and mechanical fit before selection.

UN38.3
UL1973
192V Ultra-High VoltageMaximized efficiency & reduced cable heat
3U Rack-Mount DesignFor compatible built-in UPS models; verify fit and interface
7C High-Rate DischargeDelivers 42A max continuous current
60S2P ArchitectureAdvanced cell stringing for 1152Wh power

High Voltage Series (Short Backup)

This 192V battery pack is intended for compatible 3U built-in high-voltage UPS applications. Confirm the UPS DC bus, charging profile, BMS interface, connector and installation envelope against the specific system before ordering.

  • Ultra-High-Rate Discharge: Supports up to 7C discharge rates to manage severe loads.
  • Intelligent BMS: Protection functions include overcharge, over-discharge, over-temperature, over-current and short-circuit protection; confirm thresholds and interface behavior for the final configuration.
  • Form Factor Efficiency: The volume and weight are about 1/3 to 2/3 of comparable lead-acid battery banks.
  • Extended Longevity: Service life depends on the final configuration, charge settings, operating temperature and duty cycle. Confirm expected service-life requirements for the intended application.

Typical applications include:

  • Enterprise UPS systems ≤ 8 kVA
  • Server rooms / data centers
  • Telecom & network equipment
  • Industrial control systems

Mechanical Dimensions (L×W×H): 520 × 214 × 120 mm

192V 6Ah 3U 2D Dimension Diagram
Electrical Specifications
Nominal Voltage192V
Nominal Capacity6Ah
Power1152Wh
Internal Resistance≤ 530 mΩ
Self-dischargeLess than 1% per month
Adaptable for UPS≤ 8KVA
Discharge Specifications
Backup TimeDepends on UPS load, efficiency and operating conditions; request a system-specific estimate.
Maximum Continuous Discharge Current42A
Over-discharge Protection Voltage150V
Under-voltage Recovery Voltage162V
Short-circuit ProtectionAvailable
Communication & Compliance
Communication MethodRS485/RS232
Applicable standards & documentationConfirm scope for the final configuration and destination market; request applicable records.
Mechanical Specifications
CellIFR26650-3000mAh
Number of Battery Strings60S2P
Dimensions (L×W×H)520 × 214 × 120 mm
Weight17.5 Kg
Output TerminalsAnderson SB50
Shell MaterialSPCC
IP RatingIP21
Charge Specifications
Charge Current6A
Charge Voltage216V
Overcharge Protection Voltage216V
Over-voltage Recovery Voltage213V
Balanced Start Voltage204V
Temperature Specifications
Discharge Temperature-20 to 60°C
Charge Temperature0 to 45°C
Storage Temperature-5 to 45°C
BMS Overtemperature Protection65 ± 5°C
BMS Overtemperature Protection Recovery55 ± 5°C

UPS battery selection & project planning

192V 6Ah LiFePO4 UPS battery in a 3U format for 8kVA-class systems

This page presents a 192V, 6Ah (1,152Wh) LiFePO4 pack in a 3U enclosure for UPS systems up to 8kVA. The listed 60S2P configuration, 42A maximum continuous current, 150V protection cutoff and 162V recovery value distinguish its high-voltage system interface from lower-voltage products.

UPS compatibility and replacement checks

How to interpret this configuration

Compatibility begins with the UPS DC battery bus and charge profile. Compare the required continuous current with the listed 42A limit, and verify cutoff behavior, BMS communication, connection method and mechanical fit against the target 192V UPS documentation.

Typical system context: The 3U, 192V configuration is differentiated for compatible high-voltage UPS platforms in enterprise server/network rooms and critical control installations where the system is designed for a 192V battery bus. The page’s 8kVA class is not sufficient to establish fit; confirm the UPS model and current window.

Interface and installation details to confirm

  • Cell configuration listed: 60S2P; communication: RS485/RS232; output terminals: Anderson SB50.
  • The 3U enclosure is listed at 520 × 214 × 120 mm, with a 17.5kg listed weight and IP21 rating.
  • The page lists 150V over-discharge protection and 162V recovery; confirm these values for the quoted configuration and UPS.

LiFePO4 retrofit checklist

  • Confirm a 192V DC battery architecture and LiFePO4-compatible charge profile.
  • Check the required current against 42A maximum continuous and establish any transient requirement.
  • Verify the listed 150V cutoff / 162V recovery and RS232/RS485 protocol/pinout.
  • Measure the 3U envelope, mounting, connector clearance and cable access before approving the retrofit.

Runtime planning and OEM/ODM project intake

Plan from the actual UPS load

No fixed runtime is stated for this configuration. Estimate runtime from the actual UPS load curve and usable energy after losses and cutoffs; do not derive a guaranteed duration from the 1,152Wh nominal listing alone. Provide UPS model, load in watts, battery bus/cutoff and required ride-through time for a project-specific discussion.

What to include in a quotation request

Include UPS make/model, nominal battery bus and charge/cutoff window, measured load, current profile, required runtime, SB50 details, RS232/RS485 protocol, 3U space and quantity.

For OEM/ODM projects, supply the UPS model, bus and charge limits, 3U rack drawing, current profile, SB50 wiring, communication protocol and quantity. Pack/BMS and mechanical details can then be aligned with the project; the page does not promise universal compatibility or a fixed runtime.

Discuss this UPS configuration

Technical Insights & Support

Is this 192V LiFePO4 UPS battery compatible with my existing UPS system?
This 192V LiFePO4 UPS battery is designed to match UPS systems with a DC bus around 192V. Compatibility depends on your UPS’s charging profile and BMS settings. For best results, please refer to your UPS manufacturer’s specification or contact us with your UPS model details.
What is the estimated backup time for this UPS battery?
Backup time is not a fixed value for every installation. It depends on the connected load profile, UPS conversion efficiency, discharge limits, battery condition and operating temperature. Share the UPS model, expected load, DC bus and required runtime to request a configuration-specific estimate.
Why use a 192V high-voltage battery instead of a standard 48V system?
At the same power level, a higher DC bus can reduce current compared with a 48V system. Actual cable sizing, losses and system efficiency depend on the UPS architecture, wiring and operating conditions.
Does it fit easily in standard server racks?
This pack uses a 3U rack-mount format and the listed dimensions are 520 × 214 × 120 mm. Confirm the cabinet’s available space, mounting points, cable clearance, connector position and retention method before ordering.
What protection features are built into this battery?
The listed BMS functions include overcharge, over-discharge, over-temperature, over-current and short-circuit protection. Confirm protection thresholds and communication behavior against the final pack and UPS specifications.
Can I order a similar UPS battery with different voltage or capacity?
Yes, we support customization for UPS battery solutions. You can contact us to discuss alternative voltages, higher capacities, or communication interfaces such as RS485 or CAN. Please provide your application requirements for a tailored solution.

Blog Information

Latest insights from CLF: battery technology, energy storage, and industry updates.

Loading posts…
Get a Quote
Response within 24 Hours
✉️
Email Sales Team
📞
Call Us (24/7)
🏭
Factory Base Changsha, Hunan, China
🔒 Privacy Guaranteed:
Your design files & NDA status are strictly protected.
Inquiry Form (ESS / Battery / Harness)

By submitting this form, you agree we may contact you about your inquiry. No spam.

Scroll to Top