12.8V 6Ah Angle View
12.8V 6Ah LiFePO4 UPS Battery

12.8V 6Ah LiFePO4 UPS Battery
(0.5kVA Lead-Acid Alternative)

Specifically designed as a reliable lithium alternative to traditional sealed lead-acid (SLA) batteries in general UPS equipment up to 0.5kVA. Featuring an ultra-compact footprint and massive flexible expansion capabilities up to 4S10P.

UN38.3
CE
RoHS
UPS CompatibilityConfirm charge profile, voltage, connector and BMS/interface
7.5C High-Rate DischargeSupports up to 45A max continuous discharge
4S10P ScalabilityConnect up to 4 in series and 10 in parallel
Service Life VariesDepends on operating temperature and use conditions

Lead-acid replacement UPS lithium battery

The CLF standard-voltage UPS battery is a lithium alternative for eligible 0.5kVA UPS systems. Confirm the charging profile, voltage window, current demand, connector, dimensions and BMS/interface before ordering.

  • Installation Fit: Compare pack dimensions and weight with the available battery compartment, and confirm connector and charging requirements.
  • High-Rate Output: Supports sudden high-power demands with up to 7.5C continuous discharge.
  • Unmatched Scalability: Highly flexible system design allows up to 4 battery packs in series and 10 in parallel to meet any custom capacity requirement.
  • Integrated Protection: Smart BMS provides full defense against overcharge, over-discharge, over-temperature, over-current, and short circuits.

With a compact and lightweight design, the battery is suitable for UPS systems with limited installation space and indoor operating environments.

Typical application scenarios include:

  • Data centers and enterprise server rooms
  • Supermarket and retail backup power
  • Building systems and access control
  • Networking equipment and small industrial controls

Mechanical Dimensions (L×W×H): 150±2 × 68±2 × 94±2 mm

12.8V 6Ah 2D Dimension Diagram
Electrical Specifications
Nominal Voltage12.8V
Nominal Capacity6Ah
Power76.8Wh
Internal Resistance30mΩ
Self-discharge< 1% per month
Series-Parallel Connection4S10P Supported
Compatible with UPS≤ 0.5KVA
Discharge Specifications
Backup Time8~15 Minutes
Max Continuous Discharge Current45A
Over-discharge Protection Voltage9.2V
Over-discharge Recovery Voltage10.8V
Short Circuit ProtectionIntegrated
Mechanical & Communication
Dimensions (L×W×H)150 × 68 × 94 mm
CommunicationRS232 & RS485
Enclosure MaterialHigh-impact ABS/PC
Terminal TypeF2 Faston (Customizable)
Temperature Specifications
Discharge Temperature-20 to 60°C
Charging Temperature0 to 45°C
Storage Temperature-5 to 45°C
BMS Over-Temperature Protection65 ± 5°C
BMS Over-Temp Recovery55 ± 5°C

UPS battery selection & project planning

12.8V 6Ah LiFePO4 UPS battery for compact 0.5kVA systems

This listing identifies a 12.8V, 6Ah (76.8Wh) pack for compatible UPS applications up to 0.5kVA. The listed 45A maximum continuous discharge and 8–15 minute backup-time reference help frame selection, but the UPS model and actual DC load determine suitability.

UPS compatibility and replacement checks

How to interpret this configuration

Treat the 0.5kVA label as a UPS class, not as a compatibility guarantee. Confirm the battery-side DC bus and charger profile first, then compare the UPS demand with the listed 45A maximum continuous current and the BMS cutoff/recovery values of 9.2V and 10.8V.

Typical system context: The listed 150 × 68 × 94 mm format and 0.5kVA class make this page most relevant to compact UPS replacements such as small-office IT, access-control panels, point-of-sale equipment and security/network devices—only where the DC bus, current and charging profile match.

Interface and installation details to confirm

  • Published envelope: 150 × 68 × 94 mm; terminal: F2 Faston, with terminal customization listed.
  • The product page lists RS232 and RS485; confirm the protocol, pinout and data points required by the UPS.
  • The page lists 4S10P under series-parallel connection, but does not define whether it describes cells or external battery-pack wiring. Confirm pack-level topology before connecting modules.

LiFePO4 retrofit checklist

  • UPS model and nominal battery-bus voltage / permitted charge window
  • Continuous and peak battery-side current plus required runtime
  • F2 terminal polarity, cable arrangement and BMS communication needs
  • Available mounting envelope and the meaning of the listed 4S10P topology

Runtime planning and OEM/ODM project intake

Plan from the actual UPS load

The page lists 8–15 minutes as a reference, not as a result for every 0.5kVA load. Runtime changes with actual load, UPS conversion efficiency, usable battery energy, cutoff, state of charge, temperature, age and system configuration. For a project estimate, send the UPS model, measured load, DC bus, cutoff voltage and required hold-up time.

What to include in a quotation request

Send the UPS make/model, battery DC bus, charge window, load, runtime target, required quantity, F2 polarity/cable details and enclosure dimensions. This gives the project review the information needed to check the pack against the system.

For an OEM/ODM inquiry, specify whether the project needs this nominal-voltage class or a different pack, then provide the UPS interface, cable/terminal, enclosure, label and monitoring requirements. Configuration and integration details should be agreed against the target UPS before a build is quoted.

Discuss this UPS configuration

Technical Insights & Support

Can this 12.8V 6Ah LiFePO4 UPS battery replace a traditional lead-acid battery?
It may suit an eligible UPS as a lithium alternative, subject to a fit check. Confirm the charging profile, voltage window, current demand, connector, dimensions and BMS/interface before ordering.
What is the typical backup runtime with this 12.8V battery?
The product specification lists 8–15 minutes as a backup-time reference. Actual runtime varies with the UPS model and connected load. Share your UPS model, load, and required backup time so we can confirm the fit.
Does 4S10P mean I can connect several finished battery packs together?
The specification lists a 4S10P connection, but it does not define whether that notation refers to cells or external pack wiring. Do not connect finished packs in series or parallel from this label alone; confirm the permitted pack-level topology and UPS voltage window for the quoted configuration.
What protection features are included with the integrated BMS?
The battery integrates a robust BMS offering multi-layer security: overcharge protection, over-discharge protection, short-circuit protection, overcurrent protection, overtemperature protection, and internal cell balancing.
Where is this 0.5kVA battery module typically installed?
Thanks to its ultra-compact 150x68x94mm form factor, it is ideal for systems with limited installation space. Typical applications include small office IT infrastructure, building access control, supermarket backup registers, and security networking equipment.
Can I order custom voltage or capacity for my specific UPS application?
Yes, we support deep customization of LiFePO4 battery packs for specific UPS applications. Custom options include different nominal voltages, higher capacity ratings, various communication interfaces (RS485, RS232), and specific terminal connectors.

Blog Information

Latest insights from CLF: battery technology, energy storage, and industry updates.

Loading posts…
Get a Quote
Response within 24 Hours
✉️
Email Sales Team
📞
Call Us (24/7)
🏭
Factory Base Changsha, Hunan, China
🔒 Privacy Guaranteed:
Your design files & NDA status are strictly protected.
Inquiry Form (ESS / Battery / Harness)

By submitting this form, you agree we may contact you about your inquiry. No spam.

Scroll to Top