CF-PowerOne-5000W LE
(All-in-One Stackable ESS)
A 5kW single-phase hybrid inverter works with 1–6 stackable LiFePO4 battery modules. Each module stores 5.12kWh, providing 5.12–30.72kWh of system energy. Dual MPPT supports residential solar input.
CF-PowerOne-5000W LE combines a 5kW single-phase inverter with stackable LiFePO4 battery modules for residential solar and storage. Configure 1–6 modules, each rated at 5.12kWh, for 5.12–30.72kWh of system energy. Battery modules are rated IP65 and specified for indoor or outdoor-under-roof installation; avoid direct sunlight. Battery communication uses RS485/CAN.
Explore our Home Energy Storage range for related residential system configurations.
The single-phase inverter is designed for residential solar and storage. Check PV and load sizing against the project design and the applicable datasheet values.
- Dual MPPT; maximum PV input power 7.5kW and maximum PV voltage 550V.
- MPPT range 80–500V; full MPPT range for the 5kW model is 150–500V.
- Maximum inverter efficiency 98.1%; PV-to-battery efficiency 98.1%; battery-to-AC efficiency 96.8%.
- Backup output: 5.0kVA continuous and 7.5kVA peak for 10 minutes; switching time is less than 10ms. Actual supported loads depend on system configuration.
- Standby consumption below 10W; noise below 25dB; intelligent fan cooling.
For project-specific configuration, see our OEM/ODM service information.
The inverter datasheet lists PV reverse-polarity, over-current and over-voltage protection, anti-islanding, AC short-circuit protection, residual-current detection, ground-fault monitoring, insulation-resistance detection and PV arc detection (AFCI Standard). It also lists RSD Ready and VPP Ready features.
- The battery-pack datasheet states that each pack includes a built-in aerosol fire-extinguishing device.
- Typical residential uses include solar self-consumption and configured backup loads.
- Confirm the ordered configuration, electrical design and destination-market requirements before installation.
| Rated AC Output Power | 5,000 W |
| Max PV Input Power | 7,500 W |
| Max PV Voltage | 550 V |
| MPPT Range | 80–500 V |
| Full MPPT Range — 5kW Model | 150–500 V |
| Normal PV Voltage | 360 V |
| Startup Voltage | 100 V |
| MPP Trackers / PV Strings | 2 / 2 |
| Max PV Input Current | 18.5 A × 2 |
| Max PV Short-Circuit Current | 26 A × 2 |
| Battery Port Voltage Range | 40–60 V |
| Max Battery Charge/Discharge Power | 5.0 kW |
| Max Battery Port Charge/Discharge Current | 120 A |
| Max Efficiency | 98.1% |
| PV-to-Battery Efficiency | 98.1% |
| Battery-to-AC Efficiency | 96.8% |
| AC Grid Max Continuous Current | 23.0 A |
| AC Grid Max Continuous Power | 5.0 kVA |
| Nominal Grid Current | 22.8 A @220 V / 21.8 A @230 V |
| Nominal Grid Voltage | 198–242 V @220 V; 207–253 V @230 V |
| Grid Frequency | 50 / 60 Hz |
| Backup Max Continuous Power | 5.0 kVA |
| Backup Peak Power | 7.5 kVA / 10 min |
| Backup Peak Current | 34.1 A @220 V / 32.7 A @230 V |
| Switching Time | <10 ms |
| Inverter Operating Temperature | −25 to +60°C |
| Inverter Enclosure | IP65 / NEMA4X |
| Inverter Dimensions | 600 × 430 × 210 mm |
| Inverter Weight | 25 kg |
| Cooling / Noise / Standby | Intelligent fan / <25 dB / <10 W |
| Inverter Display / Interfaces | LCD / LED; RS485 / CAN / Wi-Fi / GPRS / 4G |
| Battery Module Nominal Voltage | 51.2 V |
| Battery Module Energy | 5.12 kWh |
| System Configuration | 1–6 battery modules |
| System Energy | 5.12–30.72 kWh |
| Module Working Voltage | 44.8–56.16 V |
| Module Charge Voltage | 58.4 V |
| Nominal Charge/Discharge Current | 50 A |
| Module Max Charge/Discharge Current | 100 A |
| Module Peak Current | 200 A / 3 sec |
| Cycle Life | 6000 cycles @80% DOD, 25°C / 0.5C |
| Battery Charge Temperature | 0–55°C |
| Battery Discharge Temperature | −20–60°C |
| Battery Module Dimensions | 600 × 210 × 300 mm |
| Battery Module Weight | 50.5 kg |
| Battery Module Ingress Protection | IP65 |
| Installation Environment | Indoor / outdoor under roof; avoid direct sunlight |
| Humidity | 5–95% RH, non-condensing |
| Battery Altitude | <2500 m |
| Battery Communication | RS485 / CAN |
| Battery Indicators | SOC status / LED |
| Battery Safety Device | Built-in aerosol fire-extinguishing device, as stated in the battery datasheet |