48V 12Ah LiFePO4 UPS Battery
(4kVA Backup Module)
Engineered for high-rate external UPS equipment up to 4kVA. This module provides stable backup power with an ultra-high 7C discharge rate and supports simple expansion of up to 8 packs in parallel.
External Battery (Short Backup)
The CLF Standard Voltage Series UPS Battery Pack is customized specifically for high-rate UPS equipment, perfectly suited for 1U external UPS series available on the market.
- Unmatched Expansion: Supports simple expansion with up to 8 battery packs connected in parallel.
- Ultra-High-Rate Discharge: Capable of up to 7C maximum discharge rate to handle sudden heavy loads.
- Advanced BMS Protection: Comprehensive protection against overcharge, over-discharge, over-temperature, over-current, and short circuits.
- Longevity: Features an ultra-long float charge design, lasting 4-5 times longer than lead-acid batteries with a calendar life exceeding 10 years.
Designed for reliable UPS backup applications, this battery is widely used in data centers, enterprise IT rooms, banking facilities, medical equipment, security systems, precision instruments, and commercial office environments.
Mechanical Dimensions (L×W×H): 415 × 438 × 88.5 mm
| Electrical Specifications | |
|---|---|
| Rated Voltage | 48V |
| Rated Capacity | 12Ah |
| Power | 576Wh |
| Internal Resistance | ≤ 150 mΩ |
| Self-discharge | < 1% per month |
| Series and Parallel | 8 in parallel |
| Adaptable for UPS | ≤ 4KVA |
| Discharge Specifications | |
|---|---|
| Backup Time | 8~15 minutes |
| Max Continuous Discharge Current | 84A |
| Over-discharge Protection Voltage | 39V |
| Overdischarge Recovery Voltage | 40.5V |
| Short Circuit Protection | Yes |
| Communication & Compliance | |
|---|---|
| Communication Methods | RS232/RS485 |
| Certification | UN 38.3/UL1973 |
| Mechanical Specifications | |
|---|---|
| Cell Specification | IFR26650-3000mAh |
| Battery Series | 15S4P |
| Dimensions (L×W×H) | 418 × 438 × 43 mm |
| Weight | 12 Kg |
| Output Terminal | Anderson SB50 |
| Shell Material | SPCC |
| IP Rating | IP21 |
| Charging Specifications | |
|---|---|
| Charging Current | 9A |
| Charging Voltage | 54V |
| Overcharge Protection Voltage | 54V |
| Overcharge Recovery Voltage | 51.75V |
| Balancing Activation Voltage | 51.75V |
| Temperature Specifications | |
|---|---|
| Discharge Temperature | -20 to 60°C |
| Charge Temperature | 0 to 45°C |
| Storage Temperature | -5 to 45°C |
| BMS Over-Temperature Protection | 65 ± 5°C |
| BMS Over-Temp Protection Recovery | 55 ± 5°C |